EnzyChrom™ Triglyceride Assay Kit |
ETGA-200 |
BioAssay Systems |
200 |
EUR 439 |
Description: For quantitative determination of triglyceride and evaluation of drug effects on triglyceride metabolism. Key Features: Sensitive and accurate. Use as little as 10 µL samples. Linear detection range 0.01 to 1.0 mmol/L (0.88 to 88.5 mg/dL) triglyceride. Simple and convenient. The procedure involves addition of a single working reagent and incubation for 30 min at room temperature, compatible for HTS assays. Improved reagent stability. The optimized formulation has greatly enhanced the reagent and signal stability. Method: OD570nm. Samples: Serum, plasma etc. Species: All. Procedure: Assay takes 30 min. Kit size: 200 tests. Detection limit: 0.01 mmol/L (0.88 mg/dL). |
Enzychrom Laboratories manufactures the fisher enzychrom triglyceride assay reagents distributed by Genprice. The Fisher Enzychrom Triglyceride Assay reagent is RUO (Research Use Only) to test human serum or cell culture lab samples. To purchase these products, for the MSDS, Data Sheet, protocol, storage conditions/temperature or for the concentration, please contact enzychrom. Other Fisher products are available in stock. Specificity: Fisher Category: Enzychrom Group: Triglyceride Assay
EnzyChrom™ Ammonia Assay Kit |
BioAssay Systems |
100 |
EUR 359 |
Description: For quantitative determination of ammonia/ammonium and evaluation of drug effects on their metabolism. Key Features: High sensitivity and wide linear range. Use 20 µL sample. Linear detection range 24 to 1000 µM ammonia. Homogeneous and simple procedure. Simple "mix-and-measure" procedure allows reliable quantitation of ammonia within 30 minutes. Method: OD340nm, or FL360/450nm. Samples: Serum, plasma, urine, saliva, cell culture etc. Species: All. Procedure: Assay takes 30 min. Kit size: 100 tests. Detection limit: 24 µM. |
EnzyChrom™ Oxaloacetate Assay Kit |
BioAssay Systems |
100 |
EUR 409 |
Description: For quantitative determination of oxaloacetate and evaluation of drug effects on its metabolism. Key Features: Sensitive and accurate. Linear detection range: 7 to 400 µM oxaloacetate for colorimetric assays and 1 to 40 µM for fluorimetric assays. Method: OD570nm, or FL530/585nm. Samples: Plasma, serum, tissue and culture media. Species: All. Procedure: Assay takes 20 min. Kit size: 100 tests. Detection limit: OD, FL: 4, 1 µM. |
EnzyChrom™ Acetate Assay Kit |
BioAssay Systems |
100 |
EUR 439 |
Description: For quantitative determination of acetic acid or acetate and evaluation of drug effects on acetate metabolism. Key Features: Sensitive. Use as little as 10 µL samples. Detection range: 0.20 to 20 mM acetate for colorimetric assays and 0.13 to 2 mM for fluorimetric assays. Simple. The assay involves adding a single working reagent, incubation for 30 min at room temperature and read. Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. Can be readily automated on HTS liquid handling systems for processing thousands of samples per day. Method: OD570nm, or FL530/585nm. Samples: Serum, plasma, food, agriculture and environment. Species: All. Procedure: Assay takes 30 min. Kit size: 100 tests. Detection limit: 0.13 mM. |
EnzyChrom™ Oxalate Assay Kit |
BioAssay Systems |
100 |
EUR 579 |
Description: For quantitative determination of oxalate (oxalic acid) in urine and other samples. Key Features: Sensitive and accurate. Use as little as 10 µL samples. Linear detection range in 96-well plate for 10 minute incubation: 20 to 1500 µM oxalate. Fast and convenient. Sample pre-treatment is faster and easier than using activated carbon in competitor’s assay kits. High-throughput adaptable. The procedure involves addition of a single working reagent and incubation for 10 min at room temperature. Can be automated for processing thousands of samples per day. Method: OD595nm. Samples: urine, animal and plant tissue samples. Species: All. Procedure: Assay takes 10 min. Kit size: 100 tests. Detection limit: 20 µM. |
EnzyChrom™ Maltose Assay Kit |
BioAssay Systems |
100 |
EUR 369 |
Description: For quantitative determination of maltose and evaluation of drug effects on its metabolism. Key Features: Fast and sensitive. Use of 10 µL sample. Linear detection range 2 to 500 µM maltose for colorimetric assays and 1 to 50 µM for flourimetric assays. Convenient. The procedure involves adding a single working reagent, and reading the absorbance after 60 minutes. Room temperature assay. No 37°C heater is needed. High-throughput. "Add-mix-read" type assay. Can be readily automated as a high-throughput 96-well plate assay for thousands of samples per day. Method: OD570nm, or FL530/585nm. Samples: Serum, urine, food and beverages, etc. Species: All. Procedure: Assay takes 60 min. Kit size: 100 tests. Detection limit: 2 µM. |
EnzyChrom™ Phenylalanine Assay Kit |
BioAssay Systems |
100 |
EUR 399 |
Description: For quantitative determination of L-phenylalanine and evaluation of drug effects on its metabolism. Key Features: Safe. Non-radioactive assay. Sensitive and accurate. Linear detection range of 2 - 300 µM L-phenylalanine. Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. No wash and reagent transfer steps are involved. Can be readily automated on HTS liquid handling systems for processing thousands of samples per day. Method: FL530/595nm. Samples: Serum, urine etc. Species: All. Procedure: Assay takes 30 min. Kit size: 100 tests. Detection limit: 2 µM. |
EnzyChrom™ Phospholipd Assay Kit |
BioAssay Systems |
100 |
EUR 459 |
Description: For quantitative determination of phospholipid and evaluation of drug effects on its metabolism. Key Features: Sensitive. Use 20 µL samples. Linear detection range: colorimetric assay 3 - 200 µM, fluorimetric assay 0.6 - 20 µM phospholipid. Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. Can be readily automated on HTS liquid handling systems for processing thousands of samples per day. Method: OD570nm, or FL530/585nm. Samples: Biological. Species: All. Procedure: Assay takes 20 min. Kit size: 100 tests. Detection limit: OD, FL: 3, 0.6 µM. |
Triglyceride Assay information
Triglycerides Assay Kit |
abx098461-Hitachi7020R140ml4R240ml1 |
Abbexa |
Hitachi 7020; R1: 40ml×4 R2: 40ml×1 |
EUR 340.8 |
|
Triglycerides Assay Kit |
abx098461-Hitachi7060R190ml2R245ml1 |
Abbexa |
Hitachi 7060; R1: 90ml×2 R2: 45ml×1 |
EUR 322.8 |
|
Triglycerides Assay Kit |
abx098461-Hitachi7170R132ml4R28ml4 |
Abbexa |
Hitachi 7170; R1: 32ml×4 R2: 8ml×4 |
EUR 360 |
|
Triglycerides Assay Kit |
abx098461-Toshiba40R140ml4R240ml1 |
Abbexa |
Toshiba 40; R1: 40ml×4 R2: 40ml×1 |
EUR 340.8 |
|
EZScreen? Triglyceride Quantification Colorimetric Assay Kit (384-well) |
K952-400 |
Biovision |
each |
EUR 751.2 |
EnzyChrom™ Malate Assay Kit |
EMAL-100 |
BioAssay Systems |
100 |
EUR 419 |
Description: For quantitative determination of L-malate (L-malic acid) and drug effects on malate metabolism. Key Features: Fast and sensitive. Use of 20 µL sample. Linear detection range 0.02 to 2 mM L-malate in 96-well plate assay. Convenient. The procedure involves adding a single working reagent, and reading the optical density at time 15 minutes. Room temperature assay. No 37°C heater is needed. High-throughput. Can be readily automated as a high-throughput 96-well plate assay for thousands of samples per day. Method: OD565nm. Samples: Malate in food, juice, beverage and other agricultural products. Species: All. Procedure: Assay takes 15 min. Kit size: 100 tests. Detection limit: 0.02 mM. |
EnzyChrom™ Kinase Assay Kit |
EKIN-400 |
BioAssay Systems |
400 |
EUR 299 |
Description: Rapid homogenous assay for protein kinase activity and high-throughput screen for kinase inhibitors. Key Features: Safe. Non-radioactive assay. Sensitive and accurate. As low as 0.01 U/L kinase can be quantified. Homogeneous and convenient. "Mix-incubate-measure" type assay. The whole assay involves adding a single working reagent and incubation for 10 min at room temperature. Robust and amenable to HTS: Assay can tolerate up to 300 µM ATP and 10% dimethylsulfoxide (DMSO). Z factors of > 0.6 are routinely observed in 96/384-well plates. Can be readily automated on HTS liquid handling systems for tens of thousands of assays per day. Method: FL530/585nm. Samples: All kinases. Species: All. Procedure: Assay takes 10 min. Kit size: 400 tests. Detection limit: 0.01 U/L. |
EnzyChrom™ Starch Assay Kit |
E2ST-100 |
BioAssay Systems |
100 |
EUR 419 |
Description: For quantitative determination of starch and evaluation of drug effects on starch metabolism. Key Features: Use as little as 10 µL samples. Linear detection range: 2 to 200 µg/mL starch for colorimetric assays and 0.2 to 20 µg/mL for fluorimetric assays. Method: OD570nm, or FL530/585nm. Samples: Biological, agriculture, food etc. Species: All. Procedure: Assay takes 30 min. Kit size: 100 tests. Detection limit: 2 µg/mL. |
EnzyChrom™ Ammonia Assay Kit |
ENH3-100 |
BioAssay Systems |
100 |
EUR 359 |
Description: For quantitative determination of ammonia/ammonium and evaluation of drug effects on their metabolism. Key Features: High sensitivity and wide linear range. Use 20 µL sample. Linear detection range 24 to 1000 µM ammonia. Homogeneous and simple procedure. Simple "mix-and-measure" procedure allows reliable quantitation of ammonia within 30 minutes. Method: OD340nm, or FL360/450nm. Samples: Serum, plasma, urine, saliva, cell culture etc. Species: All. Procedure: Assay takes 30 min. Kit size: 100 tests. Detection limit: 24 µM. |
EnzyChrom™ Acetate Assay Kit |
EOAC-100 |
BioAssay Systems |
100 |
EUR 439 |
Description: For quantitative determination of acetic acid or acetate and evaluation of drug effects on acetate metabolism. Key Features: Sensitive. Use as little as 10 µL samples. Detection range: 0.20 to 20 mM acetate for colorimetric assays and 0.13 to 2 mM for fluorimetric assays. Simple. The assay involves adding a single working reagent, incubation for 30 min at room temperature and read. Convenient and high-throughput. Homogeneous "mix-incubate-measure" type assay. Can be readily automated on HTS liquid handling systems for processing thousands of samples per day. Method: OD570nm, or FL530/585nm. Samples: Serum, plasma, food, agriculture and environment. Species: All. Procedure: Assay takes 30 min. Kit size: 100 tests. Detection limit: 0.13 mM. |
EnzyChrom™ Oxalate Assay Kit |
EOXA-100 |
BioAssay Systems |
100 |
EUR 579 |
Description: For quantitative determination of oxalate (oxalic acid) in urine and other samples. Key Features: Sensitive and accurate. Use as little as 10 µL samples. Linear detection range in 96-well plate for 10 minute incubation: 20 to 1500 µM oxalate. Fast and convenient. Sample pre-treatment is faster and easier than using activated carbon in competitor’s assay kits. High-throughput adaptable. The procedure involves addition of a single working reagent and incubation for 10 min at room temperature. Can be automated for processing thousands of samples per day. Method: OD595nm. Samples: urine, animal and plant tissue samples. Species: All. Procedure: Assay takes 10 min. Kit size: 100 tests. Detection limit: 20 µM. |
EnzyChrom™ Maltose Assay Kit |
EMLT-100 |
BioAssay Systems |
100 |
EUR 369 |
Description: For quantitative determination of maltose and evaluation of drug effects on its metabolism. Key Features: Fast and sensitive. Use of 10 µL sample. Linear detection range 2 to 500 µM maltose for colorimetric assays and 1 to 50 µM for flourimetric assays. Convenient. The procedure involves adding a single working reagent, and reading the absorbance after 60 minutes. Room temperature assay. No 37°C heater is needed. High-throughput. "Add-mix-read" type assay. Can be readily automated as a high-throughput 96-well plate assay for thousands of samples per day. Method: OD570nm, or FL530/585nm. Samples: Serum, urine, food and beverages, etc. Species: All. Procedure: Assay takes 60 min. Kit size: 100 tests. Detection limit: 2 µM. |
EnzyChrom™ Lactose Assay Kit |
ELAC-100 |
BioAssay Systems |
100 |
EUR 429 |
Description: For quantitative determination of lactose and evaluation of drug effects on lactose metabolism. Key Features: Sensitive. Use as little as 20 µL samples. Linear detection range in 96-well plate: 17 to 2000 µM lactose for colorimetric assays and 6 to 100 µM for fluorimetric assays. Convenient and high-throughput. Robust and homogeneous "mix-incubate-measure" type assay. Can be readily automated on HTS liquid handling systems for processing thousands of samples per day. Method: OD570nm, or FL530/585nm. Samples: Biological (milk), food and agriculture etc. Species: All. Procedure: Assay takes 30 min. Kit size: 100 tests. Detection limit: 6 µM. |
EnzyChrom™ Glucose Assay Kit |
EBGL-100 |
BioAssay Systems |
100 |
EUR 379 |
Description: For quantitative determination of glucose and evaluation of drug effects on glucose metabolism. Key Features: Sensitive and accurate. Use as little as 20 µL samples. Linear detection range in 96-well plate: 5 to 300 µM (90 µg/dL to 5.4 mg/dL) glucose for colorimetric assays and 1 to 30 µM for fluorimetric assays. Simple and high-throughput. The procedure involves addition of a single working reagent and incubation for 30 min at room temperature. Method: OD570nm, or FL530/585nm. Samples: Serum, plasma, urine, saliva, milk, culture medium, food, agriculture etc. Species: All. Procedure: Assay takes 40 min. Kit size: 100 tests. Detection limit: 5 µM. |
EnzyChrom™ Lactate Assay Kit |
ECLC-100 |
BioAssay Systems |
100 |
EUR 439 |
Description: For quantitative determination of L-lactate (L-lactic acid) and evaluation of drug effects on its metabolism. Key Features: Sensitive and accurate. Detection limit of 0.05 mM and linearity up to 2 mM L-Lactate in 96-well plate assay. For cell culture samples containing phenol red: detection limit of 0.1 mM and linearity up to 1 mM L-Lactate in 96-well plate assay. Convenient. The procedure involves adding a single working reagent, and reading the optical density at time zero and at 20 min. Room temperature assay. No 37°C heater is needed. High-throughput. Can be readily automated as a high-throughput 96-well plate assay for thousands of samples per day. Method: OD565nm. Samples: Serum, plasma, cell culture media etc. Species: All. Procedure: Assay takes 20 min. Kit size: 100 tests. Detection limit: 0.05 mM. |
EnzyChrom NADP/NADPH Assay Kit |
ECNP-100 |
BioAssay Systems |
100 |
EUR 537.6 |
Description: Quantitative determination of NADP and NADPH by colorimetric (565nm) method. Procedure: 30 min. Kit size: 100 tests. Detection limit: 0.1 µM. Shelf life: 6 months. Shipping: on ice; storage: -20°C. |
EnzyChrom™ Ethanol Assay Kit |
ECET-100 |
BioAssay Systems |
100 |
EUR 419 |
Description: For quantitative determination of ethanol and evaluation of drug effects on alcohol metabolism. Key Features: Sensitive and accurate. Detection limit 0.0008 vol % (140 µM or 8 ppm), linearity up to 0.1% ethanol in 96-well plate assay. Convenient. The procedure involves adding working reagent, incubating for 30 min and stopping reaction. No 37°C heater is needed. High-throughput. Can be readily automated as a high-throughput 96-well plate assay for thousands of samples per day. Method: OD565nm (Enzymatic). Samples: Serum, plasma, urine, saliva samples etc. Species: All. Procedure: Assay takes 30 min. Kit size: 100 tests. Detection limit: 0.0008%. |